Topas SPT-140油雾分离器原版资料

The test rigs purpose is the testing of oil mist separators re capture rate, flowrate curve (pressur
下载次数:413 浏览次数:876发布时间:2016-03-15 17:08
允许查看的会员等级:非会员   普通会员   高级会员   VIP会员   

文档详情

Separator Performance Tester SPT 140 Filter Test Rig for oil mist separators 

Principle 

The test rigs purpose is the testing of oil mist separators re capture rate, flowrate curve (pressure loss relative to flowrate), pressure regulation curve and leakage. The unit to be tested will be fed with an oil aerosol (flowrate and temperature adjustable) either in positive or negative pressure conditions. The immediate vicinity of the filter is temperature controlled. During the collection efficiency measurement the separated and the let-to-pass oil amounts are measured in dependence on the volumetric flow. They are automatically recorded, applying the gravimetric method, by means of an absolute filter. The amount of oil leaving the separator can be recorded online. Additionally, the leakage of the oil drain valve can be measured. The test rig simulates the operating conditions in typical fields of oil aerosol separator application. When recording the pressure control characteristic, the .pressure in the crankcase“ is simulated in dependence on the .suction pipe pressure“ for different flow rates. 

Special Advantages  

 

a specially configured aerosol generator . a facility for gravimetric collection efficiency measurement . a multitude of sensors and controllers for the measurement of temperature and differential pressure . switch box, rack and test rig control 

 

The test rig requires certain media supply connections as electric power, pressurized air and cooling water connecting lines. The cooling system permits either to emit the exhaust air in a common discharge system or to conduct a recalculated air operation. It is recommended to connect to an exhaust system for safety reasons. 

A special technical solution applying a backup filter was developed to allow the determination of the separation performance of the unit under test over a determined period under constant test conditions. Two filters, each of them separately replaceable, are alternately connected. In the start-up period initially the first filter is used until the test conditions do not vary anymore. For the measurement itself it is changed over to the second filter. 

 